Outdoor Central Tube Fiber Optic Cable GYXTW Single Mode Optical Cable 2-12 Core Fiber Cable

Model NO.: GYXTW
Core: Multicore
Certification: RoHS, CE, ISO9001
Brand: Hanxin
Sheath Material: Crosslinking
Fiber Count: 2-12 Core
Loose Tube: 2.0-2.2mm
Strength Member: 1.0-1.2mm Steel Wire
Outer Jacket: 8.0-8.6mm PE
Length: 4-6km/Drum
Trademark: HANXIN
Transport Package: 1000/2000/3000
Specification: 2-12 core
Origin: Zhejiang
HS Code: 8544700000
Model NO.: GYXTW
Core: Multicore
Certification: RoHS, CE, ISO9001
Brand: Hanxin
Sheath Material: Crosslinking
Fiber Count: 2-12 Core
Loose Tube: 2.0-2.2mm
Strength Member: 1.0-1.2mm Steel Wire
Outer Jacket: 8.0-8.6mm PE
Length: 4-6km/Drum
Trademark: HANXIN
Transport Package: 1000/2000/3000
Specification: 2-12 core
Origin: Zhejiang
HS Code: 8544700000
 GYxtw  Optical cable 
Outdoor Central Tube Fiber Optic Cable GYXTW Single Mode Optical Cable 2-12 Core Fiber Cable

 Physical Properties
Fiber Count Nominal Weight(kg/km) Nominal Weight(lb/kft) Nominal Outer Diameter(mm) Nominal Outer Diameter(in) Maximum Pulling Load
Installation(N/Ib) In Service(N/Ib)
2-24 389.0 261.07 12.6*25.1 0.50*0.99 2670/600 890/200
36-72 429.0 287.92 14.7*27.1 0.58*1.07 2670/600 890/200
96-144 571.0 383.22 20.2*32.6 0.80*1.29 2670/600 890/200
2-24 303.0 203.36 9.1*21.5 0.36*0.85 2670/600 890/200
36-72 332.0 222.82 11.1*23.5 0.44*0.93 2670/600 890/200
96-144 417.0 279.87 15.9*28.3 0.63*1.12 2670/600 890/200

   Physical Properties
Fiber Count Nominal Weight(kg/km) Nominal Weight(lb/kft) Nominal Outer Diameter(mm) Nominal Outer Diameter(in) Maximum Pulling Load
Installation(N/Ib) In Service(N/Ib)
2-24 389.0 261.07 12.6*25.1 0.50*0.99 2670/600 890/200
36-72 429.0 287.92 14.7*27.1 0.58*1.07 2670/600 890/200
96-144 571.0 383.22 20.2*32.6 0.80*1.29 2670/600 890/200
   Mechanical Properties
Minimum Bending Radius:   Maximum Compressive Load: 4000N for unarmored cables;
Under installation: 20×OD   6000N for armoured cables
During operation 0×OD for unarmoured cables Repeated Impact: 4.4 N.m (J)
  20×OD for armoured cables Twist (Torsion): 180×10 times, 125×OD
Temperature Range:   Cyclic Flexing: 25 cycles for armoured cables.
Operating Temperature Range: -40ºC(-40ºF) to +70ºC(+158ºF)   100 cycles for unarmoured cables.
Storage Temperature Range: -50ºC(-58ºF) to +70ºC(+158ºF) Crush Resistance: 220N/cm (125lb/in)
   Fiber Compliance
Temperature Cycling 
Tensile Strength 
Crush 
Impact 
Repeated Bending 
Torsion 
Kink 
Cable Bend 
Cool Bend
IEC60794-1-2-F2 
IEC60794-1-2-E1A
IEC60794-1-2-E3 
IEC60794-1-2-E4 
IEC60794-1-2-E6 
IEC60794-1-2-E7 
IEC60794-1-2-E10 
IEC60794-1-2-E11 
IEC60794-1-2-E11
   Safety Compliance
General Purpose Grade Flammability Test: OFN (UL1581)
Riser Grade Flammability Test: OFNR/FT4 (UL1666)
Plenum Grade Flammability Test: OFNP/FT6 (UL 910)
FRPVC Grade Flammability Test: IEC60332-1
LSZH Grade Halogen Content Test: IEC 60754-1 
Acidity Test: IEC 60754; 
Smoke Emission Test: IEC61034-1/2
LSFROH Grade  Halogen Content Test: IEC 60754-1 
Acidity Test: IEC 60754; 
Smoke Emission Test: IEC61034-1/2 
Flammability Test: IEC60332-1 & IEC 60332-3C/A
FR Grade Fire Resistance Test : IEC 60331 / BS 6387 CW
Outdoor Central Tube Fiber Optic Cable GYXTW Single Mode Optical Cable 2-12 Core Fiber Cable
Outdoor Central Tube Fiber Optic Cable GYXTW Single Mode Optical Cable 2-12 Core Fiber Cable

   GYxtw  Optical cable 
Outdoor Central Tube Fiber Optic Cable GYXTW Single Mode Optical Cable 2-12 Core Fiber Cable

 Physical Properties
Fiber Count Nominal Weight(kg/km) Nominal Weight(lb/kft) Nominal Outer Diameter(mm) Nominal Outer Diameter(in) Maximum Pulling Load
Installation(N/Ib) In Service(N/Ib)
2-24 389.0 261.07 12.6*25.1 0.50*0.99 2670/600 890/200
36-72 429.0 287.92 14.7*27.1 0.58*1.07 2670/600 890/200
96-144 571.0 383.22 20.2*32.6 0.80*1.29 2670/600 890/200
2-24 303.0 203.36 9.1*21.5 0.36*0.85 2670/600 890/200
36-72 332.0 222.82 11.1*23.5 0.44*0.93 2670/600 890/200
96-144 417.0 279.87 15.9*28.3 0.63*1.12 2670/600 890/200

   Physical Properties
Fiber Count Nominal Weight(kg/km) Nominal Weight(lb/kft) Nominal Outer Diameter(mm) Nominal Outer Diameter(in) Maximum Pulling Load
Installation(N/Ib) In Service(N/Ib)
2-24 389.0 261.07 12.6*25.1 0.50*0.99 2670/600 890/200
36-72 429.0 287.92 14.7*27.1 0.58*1.07 2670/600 890/200
96-144 571.0 383.22 20.2*32.6 0.80*1.29 2670/600 890/200
   Mechanical Properties
Minimum Bending Radius:   Maximum Compressive Load: 4000N for unarmored cables;
Under installation: 20×OD   6000N for armoured cables
During operation 0×OD for unarmoured cables Repeated Impact: 4.4 N.m (J)
  20×OD for armoured cables Twist (Torsion): 180×10 times, 125×OD
Temperature Range:   Cyclic Flexing: 25 cycles for armoured cables.
Operating Temperature Range: -40ºC(-40ºF) to +70ºC(+158ºF)   100 cycles for unarmoured cables.
Storage Temperature Range: -50ºC(-58ºF) to +70ºC(+158ºF) Crush Resistance: 220N/cm (125lb/in)
   Fiber Compliance
Temperature Cycling 
Tensile Strength 
Crush 
Impact 
Repeated Bending 
Torsion 
Kink 
Cable Bend 
Cool Bend
IEC60794-1-2-F2 
IEC60794-1-2-E1A
IEC60794-1-2-E3 
IEC60794-1-2-E4 
IEC60794-1-2-E6 
IEC60794-1-2-E7 
IEC60794-1-2-E10 
IEC60794-1-2-E11 
IEC60794-1-2-E11
   Safety Compliance
General Purpose Grade Flammability Test: OFN (UL1581)
Riser Grade Flammability Test: OFNR/FT4 (UL1666)
Plenum Grade Flammability Test: OFNP/FT6 (UL 910)
FRPVC Grade Flammability Test: IEC60332-1
LSZH Grade Halogen Content Test: IEC 60754-1 
Acidity Test: IEC 60754; 
Smoke Emission Test: IEC61034-1/2
LSFROH Grade  Halogen Content Test: IEC 60754-1 
Acidity Test: IEC 60754; 
Smoke Emission Test: IEC61034-1/2 
Flammability Test: IEC60332-1 & IEC 60332-3C/A
FR Grade Fire Resistance Test : IEC 60331 / BS 6387 CW
Outdoor Central Tube Fiber Optic Cable GYXTW Single Mode Optical Cable 2-12 Core Fiber Cable
Outdoor Central Tube Fiber Optic Cable GYXTW Single Mode Optical Cable 2-12 Core Fiber Cable

 

Encapsulated Transformer

Encapsulated transformers are low frequency which covered in a thicker coating of insulation than typical. Often the coils are completely encased in epoxy or an epoxy and aggregate mixture. Sometimes they are referred to as [potted" or [cast coil".

The encapsulated design is especially suited for installations in harsh environments where dust, lint, moisture and corrosive contaminants are present. Typical applications include: pulp and paper plants; steel mills; food processing plants; breweries; mines; marine and shipboard installations.

Epoxy resin encapsulated safety isolating transformer PE series

Model: PE4809C-M Power: 0.5VA

This kind of transformer is PCB welding mounting type. The input can be 110V, 220V, 230V, 380V. Output is customized. Both single way and double way are available.

encapsulated transformer encapsulated transformer encapsulated transformer

Type

Encapsulated Transformer

Primary Voltage

230V

Secondary Voltage

9V

Frequency

50HZ/60HZ

Output type

Single

Rated Power

1.5VA

weihgt

82g

Ambient Temperature Ta70/B
Temperature class Class B(130℃)
Coil Structure

EI

Dimension H max 22.3/24.4mm
Dielectric Strength 230V 4200Vrms
Test

100%

OEM & ODM OEM/ODM
Certification

VDE/CE

encapsulated transformer encapsulated transformer encapsulated transformer encapsulated transformer encapsulated transformer

FAQ

1-MOQ?

We will work hard to fit your MOQ .Small purchase quantity is ok.

2-Payment term?

T/T, Western Union, Paypal, Credit Card

3-Delivery port?

Shenzhen, Guangzhou, Zhongshan, Hongkong.

4-Shipping date?

About 7 days when we check the payment.

5-Do you produce the core and bobbin by yourself

Yes.we have 2 head company,1 subsidiary company.one is bobbin factory,one is core factory,last one is transformer factory.

6-Where is your factory?

Shaanxi


Encapsulated Transformer,Step Down Transformer,Pcb Mount Transformer,Low Frequency Transformer

Shaanxi Magason-tech Electronics Co.,Ltd , https://www.magason-tech.com