Physical Properties
Fiber Count | Nominal Weight(kg/km) | Nominal Weight(lb/kft) | Nominal Outer Diameter(mm) | Nominal Outer Diameter(in) | Maximum Pulling Load | |
Installation(N/Ib) | In Service(N/Ib) | |||||
2-24 | 389.0 | 261.07 | 12.6*25.1 | 0.50*0.99 | 2670/600 | 890/200 |
36-72 | 429.0 | 287.92 | 14.7*27.1 | 0.58*1.07 | 2670/600 | 890/200 |
96-144 | 571.0 | 383.22 | 20.2*32.6 | 0.80*1.29 | 2670/600 | 890/200 |
2-24 | 303.0 | 203.36 | 9.1*21.5 | 0.36*0.85 | 2670/600 | 890/200 |
36-72 | 332.0 | 222.82 | 11.1*23.5 | 0.44*0.93 | 2670/600 | 890/200 |
96-144 | 417.0 | 279.87 | 15.9*28.3 | 0.63*1.12 | 2670/600 | 890/200 |
   Physical Properties
Fiber Count | Nominal Weight(kg/km) | Nominal Weight(lb/kft) | Nominal Outer Diameter(mm) | Nominal Outer Diameter(in) | Maximum Pulling Load | |
Installation(N/Ib) | In Service(N/Ib) | |||||
2-24 | 389.0 | 261.07 | 12.6*25.1 | 0.50*0.99 | 2670/600 | 890/200 |
36-72 | 429.0 | 287.92 | 14.7*27.1 | 0.58*1.07 | 2670/600 | 890/200 |
96-144 | 571.0 | 383.22 | 20.2*32.6 | 0.80*1.29 | 2670/600 | 890/200 |
Minimum Bending Radius: | Â | Maximum Compressive Load: | 4000N for unarmored cables; |
Under installation: | 20×OD |  | 6000N for armoured cables |
During operation | 0×OD for unarmoured cables | Repeated Impact: | 4.4 N.m (J) |
 | 20×OD for armoured cables | Twist (Torsion): | 180×10 times, 125×OD |
Temperature Range: | Â | Cyclic Flexing: | 25 cycles for armoured cables. |
Operating Temperature Range: | -40ºC(-40ºF) to +70ºC(+158ºF) |  | 100 cycles for unarmoured cables. |
Storage Temperature Range: | -50ºC(-58ºF) to +70ºC(+158ºF) | Crush Resistance: | 220N/cm (125lb/in) |
Temperature Cycling Tensile Strength Crush Impact Repeated Bending Torsion Kink Cable Bend Cool Bend |
IEC60794-1-2-F2Â IEC60794-1-2-E1A IEC60794-1-2-E3Â IEC60794-1-2-E4Â IEC60794-1-2-E6Â IEC60794-1-2-E7Â IEC60794-1-2-E10Â IEC60794-1-2-E11Â IEC60794-1-2-E11 |
General Purpose Grade | Flammability Test: OFN (UL1581) |
Riser Grade | Flammability Test: OFNR/FT4 (UL1666) |
Plenum Grade | Flammability Test: OFNP/FT6 (UL 910) |
FRPVC Grade | Flammability Test: IEC60332-1 |
LSZH Grade | Halogen Content Test: IEC 60754-1Â Acidity Test: IEC 60754;Â Smoke Emission Test: IEC61034-1/2 |
LSFROH Grade | Halogen Content Test: IEC 60754-1 Acidity Test: IEC 60754; Smoke Emission Test: IEC61034-1/2 Flammability Test: IEC60332-1 & IEC 60332-3C/A |
FR Grade | Fire Resistance Test :Â IEC 60331 /Â BS 6387 CW |
  GYxtw  Optical cableÂ
 Physical Properties
Fiber Count | Nominal Weight(kg/km) | Nominal Weight(lb/kft) | Nominal Outer Diameter(mm) | Nominal Outer Diameter(in) | Maximum Pulling Load | |
Installation(N/Ib) | In Service(N/Ib) | |||||
2-24 | 389.0 | 261.07 | 12.6*25.1 | 0.50*0.99 | 2670/600 | 890/200 |
36-72 | 429.0 | 287.92 | 14.7*27.1 | 0.58*1.07 | 2670/600 | 890/200 |
96-144 | 571.0 | 383.22 | 20.2*32.6 | 0.80*1.29 | 2670/600 | 890/200 |
2-24 | 303.0 | 203.36 | 9.1*21.5 | 0.36*0.85 | 2670/600 | 890/200 |
36-72 | 332.0 | 222.82 | 11.1*23.5 | 0.44*0.93 | 2670/600 | 890/200 |
96-144 | 417.0 | 279.87 | 15.9*28.3 | 0.63*1.12 | 2670/600 | 890/200 |
   Physical Properties
Fiber Count | Nominal Weight(kg/km) | Nominal Weight(lb/kft) | Nominal Outer Diameter(mm) | Nominal Outer Diameter(in) | Maximum Pulling Load | |
Installation(N/Ib) | In Service(N/Ib) | |||||
2-24 | 389.0 | 261.07 | 12.6*25.1 | 0.50*0.99 | 2670/600 | 890/200 |
36-72 | 429.0 | 287.92 | 14.7*27.1 | 0.58*1.07 | 2670/600 | 890/200 |
96-144 | 571.0 | 383.22 | 20.2*32.6 | 0.80*1.29 | 2670/600 | 890/200 |
Minimum Bending Radius: | Â | Maximum Compressive Load: | 4000N for unarmored cables; |
Under installation: | 20×OD |  | 6000N for armoured cables |
During operation | 0×OD for unarmoured cables | Repeated Impact: | 4.4 N.m (J) |
 | 20×OD for armoured cables | Twist (Torsion): | 180×10 times, 125×OD |
Temperature Range: | Â | Cyclic Flexing: | 25 cycles for armoured cables. |
Operating Temperature Range: | -40ºC(-40ºF) to +70ºC(+158ºF) |  | 100 cycles for unarmoured cables. |
Storage Temperature Range: | -50ºC(-58ºF) to +70ºC(+158ºF) | Crush Resistance: | 220N/cm (125lb/in) |
Temperature Cycling Tensile Strength Crush Impact Repeated Bending Torsion Kink Cable Bend Cool Bend |
IEC60794-1-2-F2Â IEC60794-1-2-E1A IEC60794-1-2-E3Â IEC60794-1-2-E4Â IEC60794-1-2-E6Â IEC60794-1-2-E7Â IEC60794-1-2-E10Â IEC60794-1-2-E11Â IEC60794-1-2-E11 |
General Purpose Grade | Flammability Test: OFN (UL1581) |
Riser Grade | Flammability Test: OFNR/FT4 (UL1666) |
Plenum Grade | Flammability Test: OFNP/FT6 (UL 910) |
FRPVC Grade | Flammability Test: IEC60332-1 |
LSZH Grade | Halogen Content Test: IEC 60754-1Â Acidity Test: IEC 60754;Â Smoke Emission Test: IEC61034-1/2 |
LSFROH Grade | Halogen Content Test: IEC 60754-1 Acidity Test: IEC 60754; Smoke Emission Test: IEC61034-1/2 Flammability Test: IEC60332-1 & IEC 60332-3C/A |
FR Grade | Fire Resistance Test :Â IEC 60331 /Â BS 6387 CW |
Â
Encapsulated transformers are low frequency which covered in a thicker coating of insulation than typical. Often the coils are completely encased in epoxy or an epoxy and aggregate mixture. Sometimes they are referred to as [potted" or [cast coil".
The encapsulated design is especially suited for installations in harsh environments where dust, lint, moisture and corrosive contaminants are present. Typical applications include: pulp and paper plants; steel mills; food processing plants; breweries; mines; marine and shipboard installations.
Epoxy resin encapsulated safety isolating transformer PE series
Model: PE4809C-M Power: 0.5VA
This kind of transformer is PCB welding mounting type. The input can be 110V, 220V, 230V, 380V. Output is customized. Both single way and double way are available.
Type |
Encapsulated Transformer |
Primary Voltage |
230V |
Secondary Voltage |
9V |
Frequency |
50HZ/60HZ |
Output type |
Single |
Rated Power |
1.5VA |
weihgt |
82g |
Ambient Temperature | Ta70/B |
Temperature class | Class B(130℃) |
Coil Structure |
EI |
Dimension H max | 22.3/24.4mm |
Dielectric Strength | 230V 4200Vrms |
Test |
100% |
OEM & ODM | OEM/ODM |
Certification |
VDE/CE |
FAQ
1-MOQ?
We will work hard to fit your MOQ .Small purchase quantity is ok.
2-Payment term?
T/T, Western Union, Paypal, Credit Card
3-Delivery port?
Shenzhen, Guangzhou, Zhongshan, Hongkong.
4-Shipping date?
About 7 days when we check the payment.
5-Do you produce the core and bobbin by yourself
Yes.we have 2 head company,1 subsidiary company.one is bobbin factory,one is core factory,last one is transformer factory.
6-Where is your factory?
Shaanxi
Encapsulated Transformer,Step Down Transformer,Pcb Mount Transformer,Low Frequency Transformer
Shaanxi Magason-tech Electronics Co.,Ltd , https://www.magason-tech.com